2006
W-Band Spectrometer with Multiple Irradiation Arms Tailored for Spin Labeler James S. Hyde, 48th Rocky Mountain Conference on Analytical Chemistry, Breckenridge, Colorado, July 23-27, 2006.
Precision Sample Tube Holders Suitable for Small Resonators. James R. Anderson, Jason W. Sidabras and James S. Hyde POSTER (pdf)
Uniform rf Fields in Loop-Gap Resonators for EPR Spectroscopy Richard R. Mett, Jason W. Sidabras and James S. Hyde POSTER (pdf)
Iris Coupling of Waveguide to Loop-Gap Resonators at High Frequencies for EPR Spectroscopy. Richard R. Mett, Jason W. Sidabras and James S. Hyde
Saturation Characteristics of Multiquantum EPR at Q-band. Patrick M. Pennington and James S. Hyde
Uniform Field Loop-Gap Resonator for use in in vivo EPR Imaging at 250 MHz.
Jason W. Sidabras, Richard R. Mett, Howard J. Halpern and James S. Hyde POSTER (pdf) Loop-Gap Resonator and Cylindrical TE011 Cavity for Aqueous Samples at 94 GHz.
Jason W. Sidabras, James S. Hyde and Richard R. Mett Physical properties of the lipid bilayer made of the total lipid extract from fiber cell plasma membranes of the calf lens
J. Widomska, J. Dillon, W. K. Subczynski Effects of dipolar, monopolar, and nonpolar carotenoids on physical properties of saturated phosphatidylcholine membranes: EPR spin-labeling study.
J. Widomska, A. Wisniewska, W. K. Subczynski
Subczynski WK. Pulse EPR Discrimination by Oxygen Transport (DOT) Method in Characterization of Membrane Domains. Faculty of Biochemistry Biophysics and Biotechnology, Jagiellonian University, Krakow, Poland, May 2006.
Subczynski WK. Carotenoids (Macular Xanthophylls) in Eye Retina. Molecular Modeling Group, Faculty of Biochemistry Biophysics and Biotechnology, Jagiellonian University, Krakow, Poland, May 2006.
Witold Karol Subczynski, "Pulse EPR Discrimination by Oxygen Transport (DOT) Method in Characterization of Membrane Domains". Lecture presented in May at Faculty of Biochemistry Biophysics and Biotechnology, Jagiellonian University, Krakow, Poland.
Witold Karol Subczynski, "Carotenoids (macular xanthophylls) in eye retina". Lecture presented in May at Molecular Modeling Group, Jagiellonian University, Krakow, Poland.
Rocky Mountain Conference 2006
W-Band Spectrometer with Multiple Irradiation Arms Tailored for Spin Labeler James S. Hyde
Precision Sample Tube Holders Suitable for Small Resonators.
James R. Anderson, Jason W. Sidabras and James S. Hyde POSTER (pdf)
Uniform rf Fields in Loop-Gap Resonators for EPR Spectroscopy
Richard R. Mett, Jason W. Sidabras and James S. Hyde
POSTER (pdf)
Iris Coupling of Waveguide to Loop-Gap Resonators at High Frequencies for EPR Spectroscopy.
Richard R. Mett, Jason W. Sidabras and James S. Hyde
Saturation Characteristics of Multiquantum EPR at Q-band.
Patrick M. Pennington and James S. Hyde
Uniform Field Loop-Gap Resonator for use in in vivo EPR Imaging at 250 MHz.
Jason W. Sidabras, Richard R. Mett, Howard J. Halpern and James S. Hyde POSTER (pdf)
Loop-Gap Resonator and Cylindrical TE011 Cavity for Aqueous Samples at 94 GHz.
Jason W. Sidabras, James S. Hyde and Richard R. Mett
Physical properties of the lipid bilayer made of the total lipid extract from fiber cell plasma membranes of the calf lens
J. Widomska, J. Dillon, W. K. Subczynski
Effects of dipolar, monopolar, and nonpolar carotenoids on physical properties of saturated phosphatidylcholine membranes: EPR spin-labeling study.
J. Widomska, A. Wisniewska, W. K. Subczynski