Pediatrics Gastroenterology

Print Page Print   EmailEmail   Bookmark Page Bookmark   RSS Feeds RSS

Recommended Protocol for Pancreatic Stimulation Test

Specimens collected via P catheter inserted through biopsy channel. Each specimen should be >0.5 ml if possible. Specimens should be placed on ice immediately, then frozen and stored at -75oC in an ultra-low freezer until ready to ship.

  1. Baseline collection (T0).
  2. Test dose of synthetic secretin (0.2 mcg) IV over 1 minute.
  3. Full dose of synthetic secretin (0.2 mcg/kg) or CCK (Kinevac) (0.02 mcg/kg) IV over 1 minute. Synthetic porcine secretin (SecreFlo) is available from Repligen (1-877-737-5443; www.secreflo.com)
  4. Specimens collected at 5, 10, 15 minutes following CCK (T5, T10, T15). We recommend using a duodenal aspiration catheter.
  5. Each specimen must be at least 0.2 ml.
  6. We will interpret results when samples are obtained as outlined in this protocol. If the protocol is not followed, we will continue to provide the results of pancreatic enzyme measurements but will be unable to interpret results.

Normal Values for individual pancreatic enzymes*:

  • Lipase > 146.0 moles/ml/min.
  • Amylase > 32.0 moles/ml/min.
  • Trypsin > 55.4 nmoles/ml/min.

*Pancreatic function can only be considered as normal when the pre-stimulated or 1 of the post-stimulated aspirates (usually 5-10 mins) attains respective levels of activity as indicated.

webmaster@mcw.edu
© 2007 Medical College of Wisconsin
Page Updated 05/05/2008